<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Weinert T</dc:creator>
  <dc:creator>Olieric N</dc:creator>
  <dc:creator>Cheng R</dc:creator>
  <dc:creator>Brünle S</dc:creator>
  <dc:creator>James D</dc:creator>
  <dc:creator>Ozerov D</dc:creator>
  <dc:creator>Gashi D</dc:creator>
  <dc:creator>Vera L</dc:creator>
  <dc:creator>Marsh M</dc:creator>
  <dc:creator>Jaeger K</dc:creator>
  <dc:creator>Dworkowski F</dc:creator>
  <dc:creator>Panepucci E</dc:creator>
  <dc:creator>Basu S</dc:creator>
  <dc:creator>Skopintsev P</dc:creator>
  <dc:creator>Doré AS</dc:creator>
  <dc:creator>Geng T</dc:creator>
  <dc:creator>Cooke RM</dc:creator>
  <dc:creator>Liang M</dc:creator>
  <dc:creator>Prota AE</dc:creator>
  <dc:creator>Panneels V</dc:creator>
  <dc:creator>Nogly P</dc:creator>
  <dc:creator>Ermler U</dc:creator>
  <dc:creator>Schertler G</dc:creator>
  <dc:creator>Hennig M</dc:creator>
  <dc:creator>Steinmetz MO</dc:creator>
  <dc:creator>Wang M</dc:creator>
  <dc:creator>Standfuss J</dc:creator>
  <dc:date>2017</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">Historically, room-temperature structure determination was succeeded by cryo-crystallography to mitigate radiation damage. Here, we demonstrate that serial millisecond crystallography at a synchrotron beamline equipped with high-viscosity injector and high frame-rate detector allows typical crystallographic experiments to be performed at room-temperature. Using a crystal scanning approach, we determine the high-resolution structure of the radiation sensitive molybdenum storage protein, demonstrate soaking of the drug colchicine into tubulin and native sulfur phasing of the human G protein-coupled adenosine receptor. Serial crystallographic data for molecular replacement already converges in 1,000-10,000 diffraction patterns, which we collected in 3 to maximally 82 minutes. Compared with serial data we collected at a free-electron laser, the synchrotron data are of slightly lower resolution, however fewer diffraction patterns are needed for de novo phasing. Overall, the data we collected by room-temperature serial crystallography are of comparable quality to cryo-crystallographic data and can be routinely collected at synchrotrons.Serial crystallography was developed for protein crystal data collection with X-ray free-electron lasers. Here the authors present several examples which show that serial crystallography using high-viscosity injectors can also be routinely employed for room-temperature data collection at synchrotrons.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/13443</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1038/s41467-017-00630-4</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/28912485</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Nature communications. - 2017</dc:source>
  <dc:title xmlns:ns1="xml" ns1:lang="en">Serial millisecond crystallography for routine room-temperature structure determination at synchrotrons.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>