<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Conte G</dc:creator>
  <dc:creator>Soejima K</dc:creator>
  <dc:creator>de Asmundis C</dc:creator>
  <dc:creator>Bruno J</dc:creator>
  <dc:creator>Cattaneo F</dc:creator>
  <dc:creator>Chierchia GB</dc:creator>
  <dc:creator>Miwa Y</dc:creator>
  <dc:creator>Caputo ML</dc:creator>
  <dc:creator>Sieira J</dc:creator>
  <dc:creator>Regoli F</dc:creator>
  <dc:creator>Moccetti T</dc:creator>
  <dc:creator>Brugada P</dc:creator>
  <dc:creator>Auricchio A</dc:creator>
  <dc:date>2020</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">AIMS
To assess the value of high-density mapping (HDM) in revealing undetected incomplete pulmonary vein isolation (PVI) after the fourth-generation cryoballoon (CB4G) ablation compared to the previous cryoballoon's versions.


METHODS AND RESULTS
Consecutive patients with paroxysmal or early-persistent atrial fibrillation (AF) undergoing CB ablation as the index procedure, assisted by HDM, were retrospectively included in this study. A total of 68 patients (52 males; mean age: 60 ± 12 years, 58 paroxysmal AF) were included, and a total of 272 veins were mapped. Fourth-generation cryoballoon with the new spiral mapping catheter (SMC) was used in 35 patients (51%). Time to PVI was determined in 102/132 (77%) and in 112/140 (80%) veins during second-generation cryoballoon/third-generation cryoballoon (CB2G/CB3G) and CB4G ablation, respectively (P = 0.66). There was a statistically significant difference in terms of discrepancy rate between the SMC and the mini-basket catheter in PV detection after CB4G and CB2G/CB3G ablation(1.4% vs. 7.6%; P = 0.01). A total of 57 patients (84%) remained free of symptomatic AF during a mean follow-up of 9.8 ± 4.6 months.


CONCLUSION
High-density mapping after cryoballoon ablation using CB4G and the new SMC identifies incomplete PVI, not detected by the new SMC, in a significantly lower proportion of veins compared to HDM performed after the other generation CB ablation.</dc:description>
  <dc:identifier>https://sonar.ch/global/documents/139417</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1093/europace/euaa160</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/32830231</dc:relation>
  <dc:source>Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. - 2020</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Ablation</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Atrial fibrillation</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Cryoballoon</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">High-density mapping</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">High-resolution mapping</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Pulmonary vein isolation</dc:subject>
  <dc:title xmlns:ns7="xml" ns7:lang="en">High-density mapping in patients undergoing ablation of atrial fibrillation with the fourth-generation cryoballoon and the new spiral mapping catheter.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
