<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Dincer C</dc:creator>
  <dc:creator>Bruch R</dc:creator>
  <dc:creator>Kling A</dc:creator>
  <dc:creator>Dittrich PS</dc:creator>
  <dc:creator>Urban GA</dc:creator>
  <dc:date>2017</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">Multiplexed point-of-care testing (xPOCT), which is simultaneous on-site detection of different analytes from a single specimen, has recently gained increasing importance for clinical diagnostics, with emerging applications in resource-limited settings (such as in the developing world, in doctors' offices, or directly at home). Nevertheless, only single-analyte approaches are typically considered as the major paradigm in many reviews of point-of-care testing. Here, we comprehensively review the present diagnostic systems and techniques for xPOCT applications. Different multiplexing technologies (e.g., bead- or array-based systems) are considered along with their detection methods (e.g., electrochemical or optical). We also address the unmet needs and challenges of xPOCT. Finally, we critically summarize the in-field applicability and the future perspectives of the presented approaches.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/143680</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1016/j.tibtech.2017.03.013</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/28456344</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Trends in biotechnology. - 2017</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">lab-on-a-chip (LOC)</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">microfluidics</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">multianalyte analysis</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">multiplexing</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">on-site testing</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">point-of-care testing (POCT)</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Animals</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Lab-On-A-Chip Devices</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Microfluidic Analytical Techniques</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Point-of-Care Systems</dc:subject>
  <dc:title xmlns:ns12="xml" ns12:lang="en">Multiplexed Point-of-Care Testing - xPOCT.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
