<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Valko Y</dc:creator>
  <dc:creator>Rosengren SM</dc:creator>
  <dc:creator>Jung HH</dc:creator>
  <dc:creator>Straumann D</dc:creator>
  <dc:creator>Landau K</dc:creator>
  <dc:creator>Weber KP</dc:creator>
  <dc:date>2016</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">OBJECTIVE
To explore whether ocular vestibular evoked myogenic potentials (oVEMP) can be used to detect a decrement in the extraocular muscle activity of patients with myasthenia gravis (MG).


METHODS
Twenty-seven patients with MG, including 13 with isolated ocular and 14 with generalized MG, and 28 healthy controls participated. We applied repetitive vibration stimuli to the forehead and recorded the activity of the inferior oblique muscle with 2 surface electrodes placed beneath the eyes. To identify the oVEMP parameters with the highest sensitivity and specificity, we evaluated the decrement over 10 stimulus repetitions at 3 different repetition rates (3 Hz, 10 Hz, and 20 Hz).


RESULTS
Repetitive stimulation at 20 Hz yielded the best differentiation between patients with MG and controls with a sensitivity of 89% and a specificity of 64% when using a unilateral decrement of ≥15.2% as cutoff. When using a bilateral decrement of ≥20.4% instead, oVEMP allowed differentiation of MG from healthy controls with 100% specificity, but slightly reduced sensitivity of 63%. For both cutoffs, sensitivity was similar in isolated ocular and generalized MG.


CONCLUSION
Our study demonstrates that the presence of an oVEMP decrement is a sensitive and specific marker for MG. This test allows direct and noninvasive examination of extraocular muscle activity, with similarly good diagnostic accuracy in ocular and generalized MG. Thus, oVEMP represents a promising diagnostic tool for MG.


CLASSIFICATION OF EVIDENCE
This study provides Class III evidence that oVEMP testing accurately identifies patients with MG with ocular symptoms (sensitivity 89%, specificity 64%).</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/166095</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1212/WNL.0000000000002383</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/26791146</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Neurology. - 2016</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Adult</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Aged</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Aged, 80 and over</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Electromyography</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Evoked Potentials</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Female</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Male</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Middle Aged</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Myasthenia Gravis</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Oculomotor Muscles</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Physical Stimulation</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Prospective Studies</dc:subject>
  <dc:subject xmlns:ns14="xml" ns14:lang="en">ROC Curve</dc:subject>
  <dc:subject xmlns:ns15="xml" ns15:lang="en">Sensitivity and Specificity</dc:subject>
  <dc:subject xmlns:ns16="xml" ns16:lang="en">Vibration</dc:subject>
  <dc:subject xmlns:ns17="xml" ns17:lang="en">Young Adult</dc:subject>
  <dc:title xmlns:ns18="xml" ns18:lang="en">Ocular vestibular evoked myogenic potentials as a test for myasthenia gravis.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>