<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Mehdizade A</dc:creator>
  <dc:creator>Lovblad KO</dc:creator>
  <dc:creator>Wilhelm KE</dc:creator>
  <dc:creator>Somon T</dc:creator>
  <dc:creator>Wetzel SG</dc:creator>
  <dc:creator>Kelekis AD</dc:creator>
  <dc:creator>Yilmaz H</dc:creator>
  <dc:creator>Abdo G</dc:creator>
  <dc:creator>Martin JB</dc:creator>
  <dc:creator>Viera JM</dc:creator>
  <dc:creator>Rüfenacht DA</dc:creator>
  <dc:date>2004</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/169157</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1007/s00234-003-1156-0</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/14968269</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Neuroradiology. - 2004</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Aged</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Bone Cements</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Female</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Fluoroscopy</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Hand</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Health Personnel</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Injections</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Male</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Pain</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Pain Management</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Palliative Care</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Radiation Dosage</dc:subject>
  <dc:subject xmlns:ns14="xml" ns14:lang="en">Radiography, Interventional</dc:subject>
  <dc:subject xmlns:ns15="xml" ns15:lang="en">Spinal Neoplasms</dc:subject>
  <dc:subject xmlns:ns16="xml" ns16:lang="en">Spine</dc:subject>
  <dc:title xmlns:ns17="xml" ns17:lang="en">Radiation dose in vertebroplasty.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
