  <dc:description xmlns:ns0="xml" ns0:lang="en">BACKGROUND
Recent studies have shown that a low clinical pretest probability may be adequate for excluding heparin-induced thrombocytopenia. However, for patients with intermediate or high pretest probability, laboratory testing is essential for confirming or refuting the diagnosis. Rapid assessment of anti-PF4/heparin-antibodies may assist clinical decision-making.


OBJECTIVES
To evaluate the performance of rapid ID-H/PF4-PaGIA. In particular, we verified reproducibility of results between plasma and serum specimens, between fresh and frozen samples, and between different ID-H/PF4-polymer lots (polystyrene beads coated with heparin/PF4-complexes).


PATIENTS/METHODS
The samples studied were 1376 plasma and 914 corresponding serum samples from patients investigated for suspected heparin-induced thrombocytopenia between January 2000 and October 2008. Anti-PF4/heparin-antibodies were assessed by ID-H/PF4-PaGIA, commercially available ELISAs and heparin-induced platelet aggregation test.


RESULTS
Among 914 paired plasma/serum samples we noted discordant results (negative vs. low-titre positive) in nine instances (1%; 95%CI, 0.4-1.6%). Overall, agreement between titres assessed in plasma vs. serum was highly significant (Spearman correlation coefficient, 0.975; P &lt; 0.0001). Forty-seven samples tested both fresh and after freezing/thawing showed a good agreement, with one discordant positive/negative result (Spearman correlation coefficient, 0.970; P &lt; 0.0001). Among 1376 plasma samples we noted a strikingly variable incidence of false negative results (none - 82%; 95%CI, 66-98%), depending on the employed ID-H/PF4-polymer lot. Faulty lots can be recognized by titrating commercial positive controls and stored samples of HIT-patients.


CONCLUSION
Laboratories performing the assay should implement stringent internal quality controls in order to recognize potentially faulty ID-H/PF4-polymer lots, thus avoiding false negative results.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/218785</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1111/j.1538-7836.2009.03507.x</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/19515091</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Journal of thrombosis and haemostasis : JTH. - 2009</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Antigen-Antibody Reactions</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Artifacts</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Autoantibodies</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Centrifugation</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Early Diagnosis</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Enzyme-Linked Immunosorbent Assay</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Freezing</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Gels</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Heparin</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Immunosorbent Techniques</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Microspheres</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Platelet Aggregation</dc:subject>
  <dc:subject xmlns:ns14="xml" ns14:lang="en">Platelet Factor 4</dc:subject>
  <dc:subject xmlns:ns15="xml" ns15:lang="en">Platelet Function Tests</dc:subject>
  <dc:subject xmlns:ns16="xml" ns16:lang="en">Polystyrenes</dc:subject>
  <dc:subject xmlns:ns17="xml" ns17:lang="en">Purpura, Thrombocytopenic, Idiopathic</dc:subject>
  <dc:subject xmlns:ns18="xml" ns18:lang="en">Reproducibility of Results</dc:subject>
  <dc:subject xmlns:ns19="xml" ns19:lang="en">Sensitivity and Specificity</dc:subject>
  <dc:subject xmlns:ns20="xml" ns20:lang="en">Specimen Handling</dc:subject>
  <dc:title xmlns:ns21="xml" ns21:lang="en">Variability of anti-PF4/heparin antibody results obtained by the rapid testing system ID-H/PF4-PaGIA.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>