<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Oranges CM</dc:creator>
  <dc:creator>Madduri S</dc:creator>
  <dc:creator>Brantner P</dc:creator>
  <dc:creator>Msallem B</dc:creator>
  <dc:creator>Giordano S</dc:creator>
  <dc:creator>Benitez B</dc:creator>
  <dc:creator>Kalbermatten DF</dc:creator>
  <dc:creator>Schaefer DJ</dc:creator>
  <dc:creator>Thieringer FM</dc:creator>
  <dc:date>2019</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">BACKGROUND/AIM
Methods to assess three-dimensionally the breast surface are increasingly used in plastic and reconstructive surgery. The aim of this study was to validate the use of the Structure Sensor 3D scanner (Occipital, Inc., Boulder, CO, USA) connected to an iPad Pro (Apple, Inc., Cupertino, CA, USA) as a novel, inexpensive and handheld three-dimensional scanning process.


MATERIALS AND METHODS
Surface images of a medical human female anatomy torso model of rigid plastic were repeatedly acquired with Structure Sensor 3D scanner and compared with those obtained using two clinically established 3D imaging systems. Digital measurements of vector and surface breast distances were analyzed using Mimics® Innovation Suite 20 medical imaging software (Materialise, Leuven, Belgium).


RESULTS
The analysis of variance (ANOVA) revealed no statistically significant difference among measurements obtained using different scanning processes for all the variables examined (p&gt;0.05).


CONCLUSION
The study demonstrates analogous practicability and reliability for surface image acquisition using the newly introduced Structure Sensor 3D scanner and other clinically established scanners.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/232503</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.21873/invivo.11548</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/31028206</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>In vivo (Athens, Greece). - 2019</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">3D scanning</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">photogrammetry</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">surface imaging</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">three-dimensional</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">virtual surgical planning</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Analysis of Variance</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Breast</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Diagnostic Imaging</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Female</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Imaging, Three-Dimensional</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Reproducibility of Results</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Tomography, X-Ray Computed</dc:subject>
  <dc:title xmlns:ns14="xml" ns14:lang="en">Three-dimensional Assessment of the Breast: Validation of a Novel, Simple and Inexpensive Scanning Process.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>