<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Pfammatter T</dc:creator>
  <dc:creator>Lachat ML</dc:creator>
  <dc:creator>Künzli A</dc:creator>
  <dc:creator>Baur DR</dc:creator>
  <dc:creator>Koppensteiner R</dc:creator>
  <dc:creator>Turina M</dc:creator>
  <dc:creator>Blum U</dc:creator>
  <dc:date>2002</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">PURPOSE
To evaluate the safety and efficacy of endovascular abdominal aortic aneurysm (AAA) repair with a commercial modular stent-graft.


METHODS
Between February 1998 and May 2000, 66 consecutive patients (56 men; mean age 70 years, range 51-87) were recruited for a single-center study to examine the safety and efficacy of the Excluder stent-graft for endovascular AAA repair. The patients were predominantly asymptomatic (2 symptomatic) and categorized as ASA III or IV (62, 94%), with aneurysms that ranged from 35 to 89 mm in diameter (mean 56). Surveillance included clinical examination and computed tomographic aortography at discharge, 6 weeks, and at 6, 12, and 24 months.


RESULTS
All endoprostheses were implanted as intended, but 1 patient succumbed to an intraprocedural brainstem infarction (1.5% 30-day mortality rate). The major and minor morbidity rates were 21% and 4.5%, respectively. Primary technical success at discharge was 68% (45/66), largely as the result of a 30% (20/66) endoleak rate. The aneurysm exclusion rate at 30 days was 88%. During the mean 5.8-month follow-up, no device migration, limb kinking, aneurysm rupture, or limb thrombosis was observed.


CONCLUSIONS
Endoluminal AAA repair with the bifurcated Excluder stent-graft is safe and efficacious in the short term. Longer surveillance will have to demonstrate if the excellent early results can be maintained over the years.</dc:description>
  <dc:identifier>https://sonar.ch/global/documents/235985</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1177/152660280200900415</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/12223008</dc:relation>
  <dc:source>Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. - 2002</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Aged</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Aged, 80 and over</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Aortic Aneurysm, Abdominal</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Blood Vessel Prosthesis</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Blood Vessel Prosthesis Implantation</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Female</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Male</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Middle Aged</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Postoperative Complications</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Prosthesis Design</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Stents</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Treatment Outcome</dc:subject>
  <dc:title xmlns:ns14="xml" ns14:lang="en">Short-term results of endovascular AAA repair with the Excluder bifurcated stent-graft.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>