<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Bertrand AM</dc:creator>
  <dc:creator>Fournier K</dc:creator>
  <dc:creator>Wick Brasey MG</dc:creator>
  <dc:creator>Kaiser ML</dc:creator>
  <dc:creator>Frischknecht R</dc:creator>
  <dc:creator>Diserens K</dc:creator>
  <dc:date>2015</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">STUDY DESIGN
Clinical measurement.


PURPOSE
The test-retest reliability of maximal grip strength measurements (MGSM) is examined in subjects for 12 weeks post-stroke together with maximal grip strength recovery and the maximal-grip and upper-extremity strength measurements' relationship with capacity and performance test scores.


METHODS
A Jamar dynamometer and the Motricity Index (MI) were used for strength measurements. The Chedoke Arm and Hand Activity Inventory and ABILHAND questionnaire for evaluating capacities and performances.


RESULTS
MGSM were reliable (Intraclass Correlation Coefficients = 0.97-0.99, Minimal Detectable Differences = 2.73-4.68 kg). Among the 34 participants, 47% did not have a measurable grip strength one week post-stroke but 50% of these recovered some strength within the first eight weeks. The MGSM and MI scores were correlated with scores of tests of capacity and performance (Spearman's Rank Correlation Coefficients = 0.69-0.94).


CONCLUSIONS
MGSM are reliable in the first weeks after a stroke.


LEVEL OF EVIDENCE
N/A.</dc:description>
  <dc:identifier>https://sonar.ch/global/documents/257528</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jht.2015.04.004</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/26206167</dc:relation>
  <dc:source>Journal of hand therapy : official journal of the American Society of Hand Therapists. - 2015</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Grip strength</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Reliability</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Stroke</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Upper extremity</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Disability Evaluation</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Female</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Hand Strength</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Male</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Middle Aged</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Muscle Strength Dynamometer</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Recovery of Function</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Reproducibility of Results</dc:subject>
  <dc:subject xmlns:ns14="xml" ns14:lang="en">Stroke</dc:subject>
  <dc:subject xmlns:ns15="xml" ns15:lang="en">Stroke Rehabilitation</dc:subject>
  <dc:title xmlns:ns16="xml" ns16:lang="en">Reliability of maximal grip strength measurements and grip strength recovery following a stroke.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>