<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>von Schulthess GK</dc:creator>
  <dc:date>2005</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">The advantages of combining PET with CT are multiple and due to the anatomic referencing and the attenuation correction capabilities, which CT introduces, as well as a resulting increase in imaging speed and more efficient use of radiopharmaceuticals. These synergistic advantages are gained with combining PET-CT, but less so when combining SPECT-CT and almost not at all, when combining PET or SPECT with MR. PET-CT in oncology has firmly established itself as the best imaging modality in many settings of tumor staging and therapy monitoring. Whether the CT used in the combined imaging approach should be a full scale contrast enhanced CT or a low mAs unenhanced scan is currently a matter of debate. The use of contrast enhanced CT in PET-CT should be guided primarily by the availability of a prior recent enhanced CT-only scan and the diagnostic questions to be answered by the PET-CT examination and not by turf issues between nuclear physicians and radiologists. The future of combined imaging seems bright, as applications in SPECT-CT and in other disease entities are emerging.</dc:description>
  <dc:identifier>https://sonar.ch/global/documents/266803</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1007/s10406-005-0127-4</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/16479661</dc:relation>
  <dc:source>European radiology. - 2005</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Image Processing, Computer-Assisted</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Neoplasm Staging</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Neoplasms</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Radiation Dosage</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Radiopharmaceuticals</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Tomography, Emission-Computed</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Tomography, Emission-Computed, Single-Photon</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Tomography, X-Ray Computed</dc:subject>
  <dc:title xmlns:ns10="xml" ns10:lang="en">Integrated modality imaging with PET-CT and SPECT-CT: CT issues.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
