  <dc:description xmlns:ns0="xml" ns0:lang="en">BACKGROUND
In an artificial pancreas (AP), the meals are either manually announced or detected and their size estimated from the blood glucose level. Both methods have limitations, which result in suboptimal postprandial glucose control. The GoCARB system is designed to provide the carbohydrate content of meals and is presented within the AP framework.


METHOD
The combined use of GoCARB with a control algorithm is assessed in a series of 12 computer simulations. The simulations are defined according to the type of the control (open or closed loop), the use or not-use of GoCARB and the diabetics' skills in carbohydrate estimation.


RESULTS
For bad estimators without GoCARB, the percentage of the time spent in target range (70-180 mg/dl) during the postprandial period is 22.5% and 66.2% for open and closed loop, respectively. When the GoCARB is used, the corresponding percentages are 99.7% and 99.8%. In case of open loop, the time spent in severe hypoglycemic events (&lt;50 mg/dl) is 33.6% without the GoCARB and is reduced to 0.0% when the GoCARB is used. In case of closed loop, the corresponding percentage is 1.4% without the GoCARB and is reduced to 0.0% with the GoCARB.


CONCLUSION
The use of GoCARB improves the control of postprandial response and glucose profiles especially in the case of open loop. However, the most efficient regulation is achieved by the combined use of the control algorithm and the GoCARB.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/268344</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1177/1932296815583333</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/25904142</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Journal of diabetes science and technology. - 2015</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">artificial pancreas</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">carbohydrate counting</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">computer vision</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">control algorithm</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">type 1 diabetes</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Algorithms</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Blood Glucose</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Cell Phone</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Computer Simulation</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Diabetes Mellitus, Type 1</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Dietary Carbohydrates</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Hyperglycemia</dc:subject>
  <dc:subject xmlns:ns14="xml" ns14:lang="en">Hypoglycemia</dc:subject>
  <dc:subject xmlns:ns15="xml" ns15:lang="en">Insulin Infusion Systems</dc:subject>
  <dc:subject xmlns:ns16="xml" ns16:lang="en">Pancreas, Artificial</dc:subject>
  <dc:subject xmlns:ns17="xml" ns17:lang="en">Postprandial Period</dc:subject>
  <dc:title xmlns:ns18="xml" ns18:lang="en">GoCARB in the Context of an Artificial Pancreas.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>