<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Guenego A</dc:creator>
  <dc:creator>Zerlauth JB</dc:creator>
  <dc:creator>Puccinelli F</dc:creator>
  <dc:creator>Hajdu S</dc:creator>
  <dc:creator>Rotzinger DC</dc:creator>
  <dc:creator>Zibold F</dc:creator>
  <dc:creator>Piechowiak EI</dc:creator>
  <dc:creator>Mordasini P</dc:creator>
  <dc:creator>Gralla J</dc:creator>
  <dc:creator>Dobrocky T</dc:creator>
  <dc:creator>Daniel RT</dc:creator>
  <dc:creator>Chapot R</dc:creator>
  <dc:creator>Mosimann PJ</dc:creator>
  <dc:date>2018</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">INTRODUCTION
Dual coaxial lumen balloon microcatheters through which small stents can be delivered have recently been described. We report a series of a new type of dual lumen balloon catheter with a parallel lumen design enabling enhanced inflation and deflation properties through which larger stents may be deployed, including flow diverters (FD).


METHODS
All aneurysms that were treated with a Copernic 2L (COP2L) dual lumen balloon catheter at our institution between February 2014 and December 2016 were assessed. Patient demographics, aneurysm characteristics, clinical and angiographic follow-up, as well as adverse events were analyzed.


RESULTS
A total of 18 aneurysms in 16 patients (14 women) were treated with the COP2L. Mean maximal aneurysm diameter was 6.4 mm, mean neck size was 3.3 mm (min 1; max 6.3), and mean aneurysm height/width was 1.1 (min 0.5; max 2.1). The COP2L was used for balloon-remodeled coiling exclusively in 2 aneurysms; coiling and FD stenting in 8; coiling and braided stent delivery in 3; coiling, braided and FD stenting in 1; and FD stenting without coiling in 4 (stenting alone). The rate of Roy-Raymond 1 (complete occlusion) changed from 22% in the immediate postoperative period to 100% at 3 months (mean imaging follow-up 8.2 months). There were three technical complications (3/16, 18.7%), including a perforation and two thromboembolic asymptomatic events that were rapidly controlled with the COP2L. There was no immediate or delayed morbidity or mortality (modified Rankin Scale score 0-1 in 100% of patients).


CONCLUSION
The COP2L is a new type of dual lumen balloon catheter that may be useful for balloon and/or stent-assisted coiling of cerebral aneurysms. The same device can be used to deliver stents up to 4.5 mm and to optimize stent/wall apposition or serve as a life-saving tool in case of thromboembolic or hemorrhagic events. Long-term efficacy and safety need to be further assessed with larger case-controlled cohorts.</dc:description>
  <dc:identifier>https://sonar.ch/global/documents/278571</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1136/neurintsurg-2017-013218</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/28754807</dc:relation>
  <dc:source>Journal of neurointerventional surgery. - 2018</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">aneurysms</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">dual lumen balloon</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">embolization</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">large stent delivery</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">onyx</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Adult</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Aged</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Balloon Occlusion</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Blood Vessel Prosthesis</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Cerebral Angiography</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Embolization, Therapeutic</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Female</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Follow-Up Studies</dc:subject>
  <dc:subject xmlns:ns14="xml" ns14:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns15="xml" ns15:lang="en">Intracranial Aneurysm</dc:subject>
  <dc:subject xmlns:ns16="xml" ns16:lang="en">Male</dc:subject>
  <dc:subject xmlns:ns17="xml" ns17:lang="en">Middle Aged</dc:subject>
  <dc:subject xmlns:ns18="xml" ns18:lang="en">Prospective Studies</dc:subject>
  <dc:subject xmlns:ns19="xml" ns19:lang="en">Retrospective Studies</dc:subject>
  <dc:subject xmlns:ns20="xml" ns20:lang="en">Stents</dc:subject>
  <dc:subject xmlns:ns21="xml" ns21:lang="en">Treatment Outcome</dc:subject>
  <dc:title xmlns:ns22="xml" ns22:lang="en">Balloon-assisted coil embolization and large stent delivery for cerebral aneurysms with a new generation of dual lumen balloons (Copernic 2L).</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
