  <dc:description xmlns:ns0="xml" ns0:lang="en">OBJECTIVE
To examine intra- and interrater reliability of thickness and cross-sectional area (CSA) measurements of the supraspinatus muscle using rehabilitative ultrasound imaging (RUSI).


METHODS
Two physical therapists acquired b-mode images of the supraspinatus muscles in twenty-five healthy subjects. Thickness and CSA were measured. Intra- and interrater reliability were examined.


RESULTS
Intrarater reliability for thickness was high, (ICC1.1 0.91) for rater 1 and (ICC1.1 0.92) for rater 2. Intrarater reliability for CSA was also high, (ICC1.1 0.90) for rater 1 and (ICC1.1 0.85) for rater 2. Interrater reliability for the thickness was high, (ICC3.1 0.86). For CSA, interrater reliability was moderate, (ICC3.1 0.70).


CONCLUSION
Supraspinatus muscle thickness and CSA can be reliably measured by physical therapists in healthy subjects. These findings confirm that RUSI has an interesting potential for physiotherapy clinical practice, especially to assess morphometric changes in skeletal muscles. Further research is needed in subjects with shoulder disorders.</dc:description>
  <dc:identifier>https://sonar.ch/global/documents/279036</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1016/j.jbmt.2013.09.009</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/24725796</dc:relation>
  <dc:source>Journal of bodywork and movement therapies. - 2014</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Morphometry</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Rehabilitative ultrasound imaging</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Reliability</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Sonography</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Supraspinatus muscle</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Adult</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Female</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Male</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Muscle, Skeletal</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Observer Variation</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Physical Therapy Modalities</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Reproducibility of Results</dc:subject>
  <dc:subject xmlns:ns14="xml" ns14:lang="en">Rotator Cuff</dc:subject>
  <dc:subject xmlns:ns15="xml" ns15:lang="en">Shoulder</dc:subject>
  <dc:subject xmlns:ns16="xml" ns16:lang="en">Ultrasonography</dc:subject>