<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Kovac M</dc:creator>
  <dc:creator>Risch L</dc:creator>
  <dc:creator>Thiel S</dc:creator>
  <dc:creator>Weber M</dc:creator>
  <dc:creator>Grossmann K</dc:creator>
  <dc:creator>Wohlwend N</dc:creator>
  <dc:creator>Lung T</dc:creator>
  <dc:creator>Hillmann D</dc:creator>
  <dc:creator>Ritzler M</dc:creator>
  <dc:creator>Bigler S</dc:creator>
  <dc:creator>Ferrara F</dc:creator>
  <dc:creator>Bodmer T</dc:creator>
  <dc:creator>Egli K</dc:creator>
  <dc:creator>Imperiali M</dc:creator>
  <dc:creator>Heer S</dc:creator>
  <dc:creator>Salimi Y</dc:creator>
  <dc:creator>Renz H</dc:creator>
  <dc:creator>Kohler P</dc:creator>
  <dc:creator>Vernazza P</dc:creator>
  <dc:creator>Kahlert CR</dc:creator>
  <dc:creator>Paprotny M</dc:creator>
  <dc:creator>Risch M</dc:creator>
  <dc:date>2020</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">While lateral flow test formats can be utilized with whole blood and low sample volumes, their diagnostic characteristics are inferior to immunoassays based on chemiluminescence immunoassay (CLIA) or enzyme-linked immunosorbent assay (ELISA) technology. CLIAs and ELISAs can be automated to a high degree but commonly require larger serum or plasma volumes for sample processing. We addressed the suitability of EDTA-anticoagulated whole blood as an alternative sample material for antibody testing against SARS-CoV-2 by electro-CLIA (ECLIA; Roche, Rotkreuz, Switzerland) and ELISA (IgG and IgA; Euroimmun, Germany). Simultaneously drawn venous serum and EDTA-anticoagulated whole blood samples from 223 individuals were included. Correction of the whole blood results for hematocrit led to a good agreement with the serum results for weakly to moderately positive antibody signals. In receiver-operating characteristic curve analysis, all three assays displayed comparable diagnostic accuracy (area under the curve (AUC)) using corrected whole blood and serum (AUCs: 0.97 for ECLIA and IgG ELISA; 0.84 for IgA ELISA). In conclusion, our results suggest that the investigated assays can reliably detect antibodies against SARS-CoV-2 in hemolyzed whole blood anticoagulated with EDTA. Correction of these results for hematocrit is suggested. This study demonstrates that the automated processing of whole blood for identification of SARS-CoV-2 antibodies with common ECLIA and ELISA methods is accurate and feasible.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/46847</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.3390/diagnostics10080593</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/32823852</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Diagnostics (Basel, Switzerland). - 2020</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">COVID-19</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">SARS-CoV-2</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">antibodies</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">preanalytics</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">sensitivity</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">serum</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">specificity</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">whole blood</dc:subject>
  <dc:title xmlns:ns9="xml" ns9:lang="en">EDTA-Anticoagulated Whole Blood for SARS-CoV-2 Antibody Testing by Electrochemiluminescence Immunoassay (ECLIA) and Enzyme-Linked Immunosorbent Assay (ELISA).</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
