<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Zihlmann MS</dc:creator>
  <dc:creator>Stacoff A</dc:creator>
  <dc:creator>Romero J</dc:creator>
  <dc:creator>Quervain IK</dc:creator>
  <dc:creator>Stüssi E</dc:creator>
  <dc:date>2005</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">Malalignment, in particular femoral component malrotation, is a commonly accepted failure mode in total knee arthroplasty. The general objective of this paper is twofold: firstly, it accentuates clinical observations of the effects of rotational malalignment in total knee arthroplasty. Secondly, it discusses the relevant parameters of existing knee joint models with regards to rotational malalignment and its biomechanical background, thereby setting a basis for future studies. To summarise, when modelling malalignment in total knee arthroplasty, the following aspects should be considered: Friction between the implant components, ligamentous and capsular structures, deformable body to model the PE inlay, and an in vivo validation of the model. Because of the large variance in anthropometrical data between individuals, future knee joint models should also incorporate individual data.</dc:description>
  <dc:identifier>https://sonar.ch/global/documents/47215</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1016/j.clinbiomech.2005.03.014</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/15961202</dc:relation>
  <dc:source>Clinical biomechanics (Bristol, Avon). - 2005</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Animals</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Arthroplasty, Replacement, Knee</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Biomechanical Phenomena</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Bone Malalignment</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Computer Simulation</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Diagnosis, Computer-Assisted</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Equipment Failure Analysis</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Joint Instability</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Knee Joint</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Knee Prosthesis</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Models, Biological</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Movement</dc:subject>
  <dc:subject xmlns:ns14="xml" ns14:lang="en">Prosthesis Failure</dc:subject>
  <dc:subject xmlns:ns15="xml" ns15:lang="en">Rotation</dc:subject>
  <dc:subject xmlns:ns16="xml" ns16:lang="en">Stress, Mechanical</dc:subject>
  <dc:subject xmlns:ns17="xml" ns17:lang="en">Surgery, Computer-Assisted</dc:subject>
  <dc:subject xmlns:ns18="xml" ns18:lang="en">Torque</dc:subject>
  <dc:title xmlns:ns19="xml" ns19:lang="en">Biomechanical background and clinical observations of rotational malalignment in TKA: literature review and consequences.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
