  <dc:description xmlns:ns0="xml" ns0:lang="en">OBJECTIVE
To evaluate the effectiveness and clinical utility of a metal artifact reduction (MAR) image reconstruction algorithm for the reduction of high-attenuation object (HAO)-related image artifacts.


METHODS
Images were quantitatively evaluated for image noise (noiseSD and noiserange) and qualitatively for artifact severity, gray-white-matter delineation, and diagnostic confidence with conventional reconstruction and after applying a MAR algorithm.


RESULTS
Metal artifact reduction reduces noiseSD and noiserange (median [interquartile range]) at the level of HAO in 1-cm distance compared with conventional reconstruction (noiseSD: 60.0 [71.4] vs 12.8 [16.1] and noiserange: 262.0 [236.8] vs 72.0 [28.3]; P &lt; 0.0001). Artifact severity (reader 1 [mean ± SD]: 1.1 ± 0.6 vs 2.4 ± 0.5, reader 2: 0.8 ± 0.6 vs 2.0 ± 0.4) at level of HAO and diagnostic confidence (reader 1: 1.6 ± 0.7 vs 2.6 ± 0.5, reader 2: 1.0 ± 0.6 vs 2.3 ± 0.7) significantly improved with MAR (P &lt; 0.0001). Metal artifact reduction did not affect gray-white-matter delineation.


CONCLUSIONS
Metal artifact reduction effectively reduces image artifacts caused by HAO and significantly improves diagnostic confidence without worsening gray-white-matter delineation.</dc:description>
  <dc:identifier>https://sonar.ch/global/documents/565</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1097/RCT.0000000000000575</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/28240633</dc:relation>
  <dc:source>Journal of computer assisted tomography. - 2017</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Adult</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Aged</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Aged, 80 and over</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Algorithms</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Artifacts</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Female</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Image Processing, Computer-Assisted</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Male</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Metals</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Middle Aged</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Reproducibility of Results</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Tomography, X-Ray Computed</dc:subject>
  <dc:title xmlns:ns14="xml" ns14:lang="en">Efficacy and Clinical Utility of a High-Attenuation Object Artifact Reduction Algorithm in Flat-Detector Image Reconstruction Compared With Standard Image Reconstruction.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>