<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Bernauer W</dc:creator>
  <dc:creator>Thiel MA</dc:creator>
  <dc:creator>Langenauer UM</dc:creator>
  <dc:creator>Rentsch KM</dc:creator>
  <dc:date>2006</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">BACKGROUND
Irrigating solutions and eye drops may contain phosphates as part of their buffer system. In the presence of epithelial keratopathy, a high concentration of phosphate favours corneal calcification. Knowledge of the phosphate concentration in artificial tear products helps to prevent this sight-threatening complication. This study gives an overview on the amount of phosphate contained in artificial tears.


METHODS
Fifty-nine samples of commercially available artificial tear preparations were tested. The quantification of phosphate was performed using the molybdate method on a Modular P autoanalyzer.


RESULTS
Twenty-six of 59 (44%) artificial tear products had a phosphate concentration above physiological levels (&gt;1.45 mmol/l). A phosphate concentration above 25 mmol/l was found in nine products (15%), a concentration higher than 50 mmol/l in three (5%).


CONCLUSIONS
Many artificial tear formulations contain unphysiological levels of phosphate, but very high concentrations are found only in a few products. These preparations have the potential to favour the formation of insoluble crystalline calcium phosphate deposits when used on a damaged corneal surface, and should therefore be used cautiously.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/57141</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1007/s00417-005-0219-9</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/16418839</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie. - 2006</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Autoanalysis</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Ophthalmic Solutions</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Phosphates</dc:subject>
  <dc:title xmlns:ns4="xml" ns4:lang="en">Phosphate concentration in artificial tears.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
