<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Tiefenauer LX</dc:creator>
  <dc:creator>Kossek S</dc:creator>
  <dc:creator>Padeste C</dc:creator>
  <dc:creator>Thiébaud P</dc:creator>
  <dc:date>1997</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">In contrast to optical immunosensors, the electrochemical detection of an immunanalytical reaction does require a labeling, but allows an easier discrimination of specific and non-specific binding. We present a concept and first results for a multivalent amperometric immunosensor system which is based on silicon technology. The capture molecule streptavidin, covalently immobilized on silica, allows the immobilization of biotinylated antigens at a defined density. A nanostructured gold electrode serving as a stable network of nanowires is expected to be beneficial for the electrochemical detection of bound ferrocene-labeled antibody molecules. The results presented focus on site-specific immobilization of streptavidin on silica and reduction of non-specific binding of proteins.</dc:description>
  <dc:identifier>https://sonar.ch/global/documents/83181</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1016/s0956-5663(97)85339-0</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/9115689</dc:relation>
  <dc:source>Biosensors &amp; bioelectronics. - 1997</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Bacterial Proteins</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Biosensing Techniques</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Electrochemistry</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Electrodes</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Enzyme-Linked Immunosorbent Assay</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Evaluation Studies as Topic</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Gold</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Silicon Dioxide</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Streptavidin</dc:subject>
  <dc:title xmlns:ns10="xml" ns10:lang="en">Towards amperometric immunosensor devices.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
