<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Giraud R</dc:creator>
  <dc:creator>Siegenthaler N</dc:creator>
  <dc:creator>Park C</dc:creator>
  <dc:creator>Beutler S</dc:creator>
  <dc:creator>Bendjelid K</dc:creator>
  <dc:date>2010</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">PURPOSE
Monitoring using transpulmonary thermodilution (TPTD) via a single thermal indicator technique allows measurement of cardiac output, extravascular lung water (EVLW) and volumetric variables.


METHODS AND RESULTS
This report describes two cases of systemic-venous circulation shunt generating early recirculation of thermal indicator with overestimation of EVLW.


CONCLUSION
In the case of recirculation of thermal indicator, the observed overestimated EVLW in absence of gas exchanges abnormality could be an indicator suggesting the search for a circulatory shunt.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/89618</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1007/s00134-010-1876-7</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/20397008</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Intensive care medicine. - 2010</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Aged</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Arteriovenous Fistula</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Cardiac Output</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Critical Illness</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Extravascular Lung Water</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Female</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Heart Septal Defects, Ventricular</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Hemodynamics</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns10="xml" ns10:lang="en">Male</dc:subject>
  <dc:subject xmlns:ns11="xml" ns11:lang="en">Monitoring, Physiologic</dc:subject>
  <dc:subject xmlns:ns12="xml" ns12:lang="en">Pulmonary Circulation</dc:subject>
  <dc:subject xmlns:ns13="xml" ns13:lang="en">Pulmonary Edema</dc:subject>
  <dc:subject xmlns:ns14="xml" ns14:lang="en">Thermodilution</dc:subject>
  <dc:subject xmlns:ns15="xml" ns15:lang="en">Young Adult</dc:subject>
  <dc:title xmlns:ns16="xml" ns16:lang="en">Transpulmonary thermodilution curves for detection of shunt.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>