<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Joda T</dc:creator>
  <dc:creator>Matthisson L</dc:creator>
  <dc:creator>Zitzmann NU</dc:creator>
  <dc:date>2020</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">The aim of this in vitro study was to analyze the impact of model aging on the accuracy of 3D-printed dental models. A maxillary full-arch reference model with prepared teeth for a three-unit fixed dental prosthesis was scanned ten times with an intraoral scanner (3Shape TRIOS Pod) and ten models were 3D printed (Straumann P-Series). All models were stored under constant conditions and digitized with a desktop scanner after 1 day; 1 week; and 2, 3, and 4 weeks. For accuracy, a best-fit algorithm was used to analyze the deviations of the abutment teeth (GFaI e.V Final Surface®). Wilcoxon Rank Sum Tests were used for comparisons with the level of significance set at α = 0.05. Deviation analysis of the tested models showed homogenous intragroup distance calculations at each timepoint. The most accurate result was for 1 day of aging (3.3 ± 1.3 µm). A continuous decrease in accuracy was observed with each aging stage from day 1 to week 4. A time-dependent difference was statistically significant after 3 weeks (p = 0.0008) and 4 weeks (p &lt; 0.0001). Based on these findings, dental models should not be used longer than 3 to 4 weeks after 3D printing for the fabrication of definitive prosthetic reconstructions.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/93518</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.3390/jcm9051436</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/32408618</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Journal of clinical medicine. - 2020</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">3D printing</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">accuracy</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">dental materials science</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">digital workflow</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">rapid prototyping</dc:subject>
  <dc:title xmlns:ns6="xml" ns6:lang="en">Impact of Aging on the Accuracy of 3D-Printed Dental Models: An In Vitro Investigation.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>