  <dc:creator>de Buys Roessingh AS</dc:creator>
  <dc:creator>Drukker A</dc:creator>
  <dc:creator>Guignard JP</dc:creator>
  <dc:date>2001</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">AIM
To evaluate the reliability of dipstick measurements of urine specific gravity (U-SG).


METHODS
Fresh urine specimens were tested for urine pH and osmolality (U-pH, U-Osm) by a pH meter and an osmometer, and for U-SG by three different methods (refractometry, automatic readout of a dipstick (Clinitek-50), and (visual) change of colour of the dipstick).


RESULTS
The correlations between the visual U-SG dipstick measurements and U-SG determined by a refractometer and the comparison of Clinitek((R))-50 dipstick U-SG measurements with U-Osm were less than optimal, showing very wide scatter of values. Only the U-SG refractometer values and U-Osm had a good linear correlation. The tested dipstick was unreliable for the bedside determination of U-SG, even after correction for U-pH, as recommended by the manufacturer.


CONCLUSIONS
Among the bedside determinations, only refractometry gives reliable U-SG results. Dipstick U-SG measurements should be abandoned.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/93557</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1136/adc.85.2.155</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/11466191</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>Archives of disease in childhood. - 2001</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Hydrogen-Ion Concentration</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Osmolar Concentration</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Point-of-Care Systems</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Reagent Kits, Diagnostic</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Refractometry</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Reproducibility of Results</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Specific Gravity</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Urinalysis</dc:subject>
  <dc:title xmlns:ns10="xml" ns10:lang="en">Dipstick measurements of urine specific gravity are unreliable.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>