<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Abdel-Sayed S</dc:creator>
  <dc:creator>Nussberger J</dc:creator>
  <dc:creator>Aubert JF</dc:creator>
  <dc:creator>Gohlke P</dc:creator>
  <dc:creator>Brunner HR</dc:creator>
  <dc:creator>Brakch N</dc:creator>
  <dc:date>2003</dc:date>
  <dc:description xmlns:ns0="xml" ns0:lang="en">BACKGROUND
Endothelin-1 is an endothelium-derived potent vasoconstrictor peptide of 21 amino acids. To establish reference values in different models of hypertension and in human subjects an assay for plasma immunoreactive endothelin-1 (ET-1) was optimized.


METHODS
ET-1 is extracted by acetone from 1 mL of plasma and subjected to a sensitive enzyme-linked immunosorbent assay.


RESULTS
The detection limit for plasma ET-1 is 0.05 fmol/mL. Mean recoveries of the 1, 2, 5, and 10 fmol of ET-1 added to 1 mL of plasma were 66%, 75%, 85%, and 92%, respectively. Within- and between-assay coefficients of variation were &lt; or =12% and &lt; or =10%, respectively. Assay accuracy was demonstrated by consistent recoveries of added ET-1 over the entire physiologic range of plasma concentrations and by the linearity of ET-1 concentrations measured in serially diluted plasma extracts (r = 0.99). No ET-1 was detected when albumin buffer was extracted instead of plasma. Using this method, we found increased ET-1 levels in plasma of three experimental rat models of hypertension: stroke prone spontaneously hypertensive rats (SP-SHR), deoxycorticosterone acetate-salt hypertensive rats, and one kidney-one clip hypertensive rats. In contrast, plasma ET-1 levels of SHR were half those of normotensive Wistar rats. In two kidney-one clip hypertensive rats, plasma ET-1 concentrations were not different from those found in sham-operated control rats. Plasma ET-1 concentrations of 37 healthy men were 0.85 +/- 0.26 fmol/ml (mean +/- SD).


CONCLUSIONS
The present assay reliably measures ET-1 levels in rat and human plasma. It allows to discriminate between different forms of hypertension with high or low circulating levels of ET-1.</dc:description>
  <dc:format>application/pdf</dc:format>
  <dc:identifier>https://sonar.ch/global/documents/93645</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>info:eu-repo/semantics/altIdentifier/doi/10.1016/s0895-7061(03)00903-8</dc:relation>
  <dc:relation>info:eu-repo/semantics/altIdentifier/pmid/12850383</dc:relation>
  <dc:rights>info:eu-repo/semantics/openAccess</dc:rights>
  <dc:source>American journal of hypertension. - 2003</dc:source>
  <dc:subject xmlns:ns1="xml" ns1:lang="en">Animals</dc:subject>
  <dc:subject xmlns:ns2="xml" ns2:lang="en">Endothelin-1</dc:subject>
  <dc:subject xmlns:ns3="xml" ns3:lang="en">Enzyme-Linked Immunosorbent Assay</dc:subject>
  <dc:subject xmlns:ns4="xml" ns4:lang="en">Humans</dc:subject>
  <dc:subject xmlns:ns5="xml" ns5:lang="en">Hypertension</dc:subject>
  <dc:subject xmlns:ns6="xml" ns6:lang="en">Male</dc:subject>
  <dc:subject xmlns:ns7="xml" ns7:lang="en">Models, Animal</dc:subject>
  <dc:subject xmlns:ns8="xml" ns8:lang="en">Rats</dc:subject>
  <dc:subject xmlns:ns9="xml" ns9:lang="en">Rats, Wistar</dc:subject>
  <dc:title xmlns:ns10="xml" ns10:lang="en">Measurement of plasma endothelin-1 in experimental hypertension and in healthy subjects.</dc:title>
  <dc:type>http://purl.org/coar/resource_type/c_6501</dc:type>
</oai_dc:dc>
