Compact static Fourier transform spectrometer with a large field of view based on liquid-crystal technology.
Journal article

Compact static Fourier transform spectrometer with a large field of view based on liquid-crystal technology.

  • 2002-03-20
Published in:
  • Applied optics. - 2002
English We present designs of static Fourier transform spectrometers that are based on a Wollaston prism with a large field of view. Besides the usual advantages of static Fourier spectrometers (large resolving power, large wave-number range, high throughput), these designs also present the advantage of using relatively cheap liquid-crystal technology. The use of twisted liquid-crystal structures gives a large field of view, which in turn gives the ability to collect more light from a divergent light source. Measurements are compared with simulations. Different simulation principles are used. We found new configurations by using twisted structures that show a large field of view.
Language
  • English
Open access status
closed
Identifiers
Persistent URL
https://sonar.ch/global/documents/112479
Statistics

Document views: 21 File downloads: