The text has been copied to the clipboard
Future prospects for SPECT imaging using the radiolanthanide terbium-155 - production and preclinical evaluation in tumor-bearing mice.
Journal article

Future prospects for SPECT imaging using the radiolanthanide terbium-155 - production and preclinical evaluation in tumor-bearing mice.

  • Müller C Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, Villigen-PSI, Switzerland.
  • Fischer E Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, Villigen-PSI, Switzerland.
  • Behe M Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, Villigen-PSI, Switzerland.
  • Köster U Institut Laue-Langevin, Grenoble, France.
  • Dorrer H Laboratory of Radiochemistry and Environmental Chemistry, Paul Scherrer Institute, Villigen-PSI, Switzerland; Laboratory of Radiochemistry and Environmental Chemistry, Department of Chemistry and Biochemistry University of Bern, Bern, Switzerland.
  • Reber J Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, Villigen-PSI, Switzerland.
  • Haller S Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, Villigen-PSI, Switzerland.
  • Cohrs S Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, Villigen-PSI, Switzerland.
  • Blanc A Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, Villigen-PSI, Switzerland.
  • Grünberg J Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, Villigen-PSI, Switzerland.
  • Bunka M Laboratory of Radiochemistry and Environmental Chemistry, Paul Scherrer Institute, Villigen-PSI, Switzerland; Laboratory of Radiochemistry and Environmental Chemistry, Department of Chemistry and Biochemistry University of Bern, Bern, Switzerland.
  • Zhernosekov K Laboratory of Radiochemistry and Environmental Chemistry, Paul Scherrer Institute, Villigen-PSI, Switzerland.
  • van der Meulen N Laboratory of Radiochemistry and Environmental Chemistry, Paul Scherrer Institute, Villigen-PSI, Switzerland.
  • Johnston K Physics Department, ISOLDE/CERN, Geneva, Switzerland.
  • Türler A Laboratory of Radiochemistry and Environmental Chemistry, Paul Scherrer Institute, Villigen-PSI, Switzerland; Laboratory of Radiochemistry and Environmental Chemistry, Department of Chemistry and Biochemistry University of Bern, Bern, Switzerland.
  • Schibli R Center for Radiopharmaceutical Sciences ETH-PSI-USZ, Paul Scherrer Institute, Villigen-PSI, Switzerland; Department of Chemistry and Applied Biosciences, ETH Zurich, Zurich, Switzerland. Electronic address: roger.schibli@psi.ch.
Show more…
  • 2013-12-24
Published in:
  • Nuclear medicine and biology. - 2014
English INTRODUCTION
We assessed the suitability of the radiolanthanide (155)Tb (t1/2=5.32 days, Eγ=87 keV (32%), 105keV (25%)) in combination with variable tumor targeted biomolecules using preclinical SPECT imaging.


METHODS
(155)Tb was produced at ISOLDE (CERN, Geneva, Switzerland) by high-energy (~1.4 GeV) proton irradiation of a tantalum target followed by ionization and on-line mass separation. (155)Tb was separated from isobar and pseudo-isobar impurities by cation exchange chromatography. Four tumor targeting molecules - a somatostatin analog (DOTATATE), a minigastrin analog (MD), a folate derivative (cm09) and an anti-L1-CAM antibody (chCE7) - were radiolabeled with (155)Tb. Imaging studies were performed in nude mice bearing AR42J, cholecystokinin-2 receptor expressing A431, KB, IGROV-1 and SKOV-3ip tumor xenografts using a dedicated small-animal SPECT/CT scanner.


RESULTS
The total yield of the two-step separation process of (155)Tb was 86%. (155)Tb was obtained in a physiological l-lactate solution suitable for direct labeling processes. The (155)Tb-labeled tumor targeted biomolecules were obtained at a reasonable specific activity and high purity (>95%). (155)Tb gave high quality, high resolution tomographic images. SPECT/CT experiments allowed excellent visualization of AR42J and CCK-2 receptor-expressing A431 tumors xenografts in mice after injection of (155)Tb-DOTATATE and (155)Tb-MD, respectively. The relatively long physical half-life of (155)Tb matched in particular the biological half-lives of (155)Tb-cm09 and (155)Tb-DTPA-chCE7 allowing SPECT imaging of KB tumors, IGROV-1 and SKOV-3ip tumors even several days after administration.


CONCLUSIONS
The radiolanthanide (155)Tb may be of particular interest for low-dose SPECT prior to therapy with a therapeutic match such as the β(-)-emitting radiolanthanides (177)Lu, (161)Tb, (166)Ho, and the pseudo-radiolanthanide (90)Y.
Language
  • English
Open access status
closed
Identifiers
Persistent URL
https://sonar.ch/global/documents/138701
Export to…

Statistics

Document views: 95 File downloads: