The text has been copied to the clipboard
Dynamic loading tests for final settling tanks
Journal article

Dynamic loading tests for final settling tanks

  • Baumer, Patrik Laboratory of Hydraulics, Hydrology and Glaciology (VAW), Swiss Federal Institute of Technology, ETH Zentrum, CH-8092 Zurich, Switzerland
  • Volkart, Peter Laboratory of Hydraulics, Hydrology and Glaciology (VAW), Swiss Federal Institute of Technology, ETH Zentrum, CH-8092 Zurich, Switzerland
  • Krebs, Peter Swiss Federal Institute for Environmental Science and Technology (EAWAG), Ueberlandstrasse 133, CH-8600 Dubendorf, Switzerland
Published in:
  • Water Science and Technology. - IWA Publishing. - 1996, vol. 34, no. 3-4, p. 267-274
English Dynamic experiments conducted in a pilot scale settling tank at Zurich's wastewater treatment plant (WWTP) are presented. The experiments were carried out with real activated sludge. They showed that vertical perforated walls transverse to the main flow direction are very beneficial particularly for wet-weather flow. The increase of the effluent suspended solids concentration is significantly dampened with dynamic hydraulic loading. Installing several perforated walls enables uniform velocity profiles to be attained, enhancing flocculation. The total sludge mass stored in the final settling tank may be increased by this system and requires special attention when the removal system is designed.
Language
  • English
Open access status
closed
Identifiers
Persistent URL
https://sonar.ch/global/documents/140372
Export to…

Statistics

Document views: 52 File downloads: