Automated Quantitative Extraction and Analysis of 4D flow Patterns in the Ascending Aorta: An intraindividual comparison at 1.5 T and 3 T.
-
Ebel S
Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig, Germany. sebastian.ebel@icloud.com.
-
Dufke J
Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig, Germany.
-
Köhler B
Department of Simulation and Graphics, University of Magdeburg, Magdeburg, Germany.
-
Preim B
Department of Simulation and Graphics, University of Magdeburg, Magdeburg, Germany.
-
Behrendt B
Department of Simulation and Graphics, University of Magdeburg, Magdeburg, Germany.
-
Riekena B
Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig, Germany.
-
Jung B
Department of Diagnostic, Interventional and paediatric Radiology, University of Bern, Bern, Switzerland.
-
Stehning C
Philips Clinical Science, Amsterdam, Netherlands.
-
Kropf S
Institute for Biometrics and Medical Informatics, University of Magdeburg, Magdeburg, Germany.
-
Grothoff M
Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig, Germany.
-
Gutberlet M
Department of Diagnostic and Interventional Radiology, University of Leipzig - Heart Centre, Leipzig, Germany.
Show more…
Published in:
- Scientific reports. - 2020
English
4D flow MRI enables quantitative assessment of helical flow. Current methods are susceptible to noise. To evaluate helical flow patterns in healthy volunteers and patients with bicuspid aortic valves (BAV) at 1.5 T and 3 T using pressure-based helix-extraction in 4D flow MRI. Two intraindividual 4D flow MRI examinations were performed at 1.5 T and 3 T in ten healthy volunteers (5 females, 32 ± 3 years) and 2 patients with BAV using different acceleration techniques (kt-GRAPPA and centra). Several new quantitative parameters for the evaluation of volumes [ml], lengths [mm] as well as temporal parameters [ms] of helical flow were introduced and analyzed using the software tool Bloodline. We found good correlations between measurements in volunteers at 1.5 T and 3 T regarding helical flow volumes (R = 0.98) and temporal existence (R = 0.99) of helices in the ascending aorta. Furthermore, we found significantly larger (11.7 vs. 77.6 ml) and longer lasting (317 vs. 769 ms) helices in patients with BAV than in volunteers. The assessed parameters do not depend on the magnetic field strength used for the acquisition. The technique of pressure-based extraction of 4D flow MRI pattern is suitable for differentiation of normal and pathological flow.
-