The text has been copied to the clipboard
Journal article

SwissFEL Aramis beamline photon diagnostics.

  • Juranić P SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Rehanek J SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Arrell CA SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Pradervand C SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Ischebeck R SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Erny C SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Heimgartner P SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Gorgisyan I CERN, Geneva 1211, Switzerland.
  • Thominet V Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Tiedtke K DESY, Notkestrasse 85, Hamburg 22607, Germany.
  • Sorokin A DESY, Notkestrasse 85, Hamburg 22607, Germany.
  • Follath R SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Makita M European XFEL, Holzkoppel 4, Schenefeld 22869, Germany.
  • Seniutinas G Paul Scherrer Institut, Villigen 5232, Switzerland.
  • David C Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Milne CJ SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Lemke H SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Radovic M SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Hauri CP SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
  • Patthey L SwissFEL, Paul Scherrer Institut, Villigen 5232, Switzerland.
Show more…
  • 2018-07-07
Published in:
  • Journal of synchrotron radiation. - 2018
English The SwissFEL Aramis beamline, covering the photon energies between 1.77 keV and 12.7 keV, features a suite of online photon diagnostics tools to help both users and FEL operators in analysing data and optimizing experimental and beamline performance. Scientists will be able to obtain information about the flux, spectrum, position, pulse length, and arrival time jitter versus the experimental laser for every photon pulse, with further information about beam shape and size available through the use of destructive screens. This manuscript is an overview of the diagnostics tools available at SwissFEL and presents their design, working principles and capabilities. It also features new developments like the first implementation of a THz-streaking based temporal diagnostics for a hard X-ray FEL, capable of measuring pulse lengths to 5 fs r.m.s. or better.
Language
  • English
Open access status
hybrid
Identifiers
Persistent URL
https://sonar.ch/global/documents/25215
Export to…

Statistics

Document views: 96 File downloads:
  • Full-text: 0