Journal article

Low-Dose Imaging in a New Preclinical Total-Body PET/CT Scanner.

  • Molinos C Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
  • Sasser T Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
  • Salmon P Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
  • Gsell W MoSAIC, KU Leuven, Leuven, Belgium.
  • Viertl D Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Lausanne, Switzerland.
  • Massey JC Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States.
  • Mińczuk K Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States.
  • Li J Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States.
  • Kundu BK Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States.
  • Berr S Department of Radiology and Medical Imaging, University of Virginia, Charlottesville, VA, United States.
  • Correcher C Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
  • Bahadur A Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
  • Attarwala AA Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
  • Stark S Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
  • Junge S Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
  • Himmelreich U MoSAIC, KU Leuven, Leuven, Belgium.
  • Prior JO Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Lausanne, Switzerland.
  • Laperre K Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
  • Van Wyk S Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
  • Heidenreich M Bruker BioSpin, Preclinical Imaging, Ettlingen, Germany.
Show more…
  • 2019-05-28
Published in:
  • Frontiers in medicine. - 2019
English Ionizing radiation constitutes a health risk to imaging scientists and study animals. Both PET and CT produce ionizing radiation. CT doses in pre-clinical in vivo imaging typically range from 50 to 1,000 mGy and biological effects in mice at this dose range have been previously described. [18F]FDG body doses in mice have been estimated to be in the range of 100 mGy for [18F]FDG. Yearly, the average whole body doses due to handling of activity by PET technologists are reported to be 3-8 mSv. A preclinical PET/CT system is presented with design features which make it suitable for small animal low-dose imaging. The CT subsystem uses a X-source power that is optimized for small animal imaging. The system design incorporates a spatial beam shaper coupled with a highly sensitive flat-panel detector and very fast acquisition (<10 s) which allows for whole body scans with doses as low as 3 mGy. The mouse total-body PET subsystem uses a detector architecture based on continuous crystals, coupled to SiPM arrays and a readout based in rows and columns. The PET field of view is 150 mm axial and 80 mm transaxial. The high solid-angle coverage of the sample and the use of continuous crystals achieve a sensitivity of 9% (NEMA) that can be leveraged for use of low tracer doses and/or performing rapid scans. The low-dose imaging capabilities of the total-body PET subsystem were tested with NEMA phantoms, in tumor models, a mouse bone metabolism scan and a rat heart dynamic scan. The CT imaging capabilities were tested in mice and in a low contrast phantom. The PET low-dose phantom and animal experiments provide evidence that image quality suitable for preclinical PET studies is achieved. Furthermore, CT image contrast using low dose scan settings was suitable as a reference for PET scans. Total-body mouse PET/CT studies could be completed with total doses of <10 mGy.
Language
  • English
Open access status
gold
Identifiers
Persistent URL
https://sonar.ch/global/documents/278024
Statistics

Document views: 67 File downloads:
  • Full-text: 0