Low-coherence interferometric tip-clearance probe.
English
We propose an all-fiber, self-calibrating, economical probe that is capable of near-real-time, single-port, simultaneous blade-to-blade tip-clearance measurements with submillimeter accuracy (typically < 100 microm, absolute) in the first stages of a gas turbine. Our probe relies on the interference between backreflected light from the blade tips during the 1-micros blade passage time and a frequency-shifted reference with variable time delay, making use of a low-coherence light source. A single optical fiber of arbitrary length connects the self-contained optics and electronics to the turbine.
-
Language
-
-
Open access status
-
green
-
Identifiers
-
-
Persistent URL
-
https://sonar.ch/global/documents/52560
Statistics
Document views: 34
File downloads: