Journal article
Synchronous and baroceptor-sensitive oscillations in skin microcirculation: evidence for central autonomic control
-
Bernardi, Luciano
Department of Internal Medicine, University of Pavia and Instituto di Ricovero e Cura a Carattere Scientifico S. Matteo, Pavia, Italy;
-
Hayoz, Daniel
Division of Hypertension, Centre Hospitalier Universitaire Vaudois, Lausanne; and
-
Wenzel, René
Department of Cardiovascular Medicine, Inselspital, Bern, Switzerland
-
Passino, Claudio
Department of Internal Medicine, University of Pavia and Instituto di Ricovero e Cura a Carattere Scientifico S. Matteo, Pavia, Italy;
-
Calciati, Alessandro
Department of Internal Medicine, University of Pavia and Instituto di Ricovero e Cura a Carattere Scientifico S. Matteo, Pavia, Italy;
-
Weber, Roger
Division of Hypertension, Centre Hospitalier Universitaire Vaudois, Lausanne; and
-
Noll, Georg
Department of Cardiovascular Medicine, Inselspital, Bern, Switzerland
Show more…
Published in:
- American Journal of Physiology-Heart and Circulatory Physiology. - American Physiological Society. - 1997, vol. 273, no. 4, p. H1867-H1878
English
To determine whether skin blood flow is local or takes part in general regulatory mechanisms, we recorded laser-Doppler flowmetry (LDF; left and right index fingers), blood pressure, muscle sympathetic nerve activity (MSNA), R-R interval, and respiration in 10 healthy volunteers and 3 subjects after sympathectomy. We evaluated 1) the synchronism of LDF fluctuations in two index fingers, 2) the relationship with autonomically mediated fluctuations in other signals, and 3) the LDF ability to respond to arterial baroreflex stimulation (by neck suction at frequencies from 0.02 to 0.20 Hz), using spectral analysis (autoregressive uni- and bivariate, time-variant algorithms). Synchronous LDF fluctuations were observed in the index fingers of healthy subjects but not in sympathectomized patients. LDF fluctuations were coherent with those obtained for blood pressure, MSNA, and R-R interval. LDF fluctuations were leading blood pressure in the low-frequency (LF; 0.1 Hz) band and lagging in the respiratory, high-frequency (HF; ∼0.25 Hz) band, suggesting passive “downstream” transmission only for HF and “upstream” transmission for LF from the microvessels. LDF fluctuations were responsive to sinusoidal neck suction up to 0.1 Hz, indicating response to sympathetic modulation. Skin blood flow thus reflects modifications determined by autonomic activity, detectable by frequency analysis of spontaneous fluctuations.
-
Language
-
-
Open access status
-
closed
-
Identifiers
-
-
Persistent URL
-
https://sonar.ch/global/documents/61264
Statistics
Document views: 17
File downloads: