High-density mapping in patients undergoing ablation of atrial fibrillation with the fourth-generation cryoballoon and the new spiral mapping catheter.
Conte GDivision of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
Soejima KDepartment of Cardiology, Kyorin University School of Medicine, Tokyo, Japan.
de Asmundis CHeart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Postgraduate Program Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium.
Bruno JDivision of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
Cattaneo FDivision of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
Chierchia GBHeart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Postgraduate Program Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium.
Miwa YDepartment of Cardiology, Kyorin University School of Medicine, Tokyo, Japan.
Caputo MLDivision of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
Sieira JHeart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Postgraduate Program Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium.
Regoli FDivision of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
Moccetti TDivision of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
Brugada PHeart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Postgraduate Program Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium.
Auricchio ADivision of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. - 2020
English
AIMS To assess the value of high-density mapping (HDM) in revealing undetected incomplete pulmonary vein isolation (PVI) after the fourth-generation cryoballoon (CB4G) ablation compared to the previous cryoballoon's versions.
METHODS AND RESULTS Consecutive patients with paroxysmal or early-persistent atrial fibrillation (AF) undergoing CB ablation as the index procedure, assisted by HDM, were retrospectively included in this study. A total of 68 patients (52 males; mean age: 60 ± 12 years, 58 paroxysmal AF) were included, and a total of 272 veins were mapped. Fourth-generation cryoballoon with the new spiral mapping catheter (SMC) was used in 35 patients (51%). Time to PVI was determined in 102/132 (77%) and in 112/140 (80%) veins during second-generation cryoballoon/third-generation cryoballoon (CB2G/CB3G) and CB4G ablation, respectively (P = 0.66). There was a statistically significant difference in terms of discrepancy rate between the SMC and the mini-basket catheter in PV detection after CB4G and CB2G/CB3G ablation(1.4% vs. 7.6%; P = 0.01). A total of 57 patients (84%) remained free of symptomatic AF during a mean follow-up of 9.8 ± 4.6 months.
CONCLUSION High-density mapping after cryoballoon ablation using CB4G and the new SMC identifies incomplete PVI, not detected by the new SMC, in a significantly lower proportion of veins compared to HDM performed after the other generation CB ablation.