The text has been copied to the clipboard
Journal article

Prophylactic, Synthetic Intraperitoneal Mesh Versus No Mesh Implantation in Patients with Fascial Dehiscence.

  • Jakob MO Department of Visceral Surgery and Medicine, Bern University Hospital, Bern, Switzerland.
  • Spari D Department of Visceral Surgery and Medicine, Bern University Hospital, Bern, Switzerland.
  • Zindel J Department of Visceral Surgery and Medicine, Bern University Hospital, Bern, Switzerland.
  • Pinworasarn T Department of Visceral Surgery and Medicine, Bern University Hospital, Bern, Switzerland.
  • Candinas D Department of Visceral Surgery and Medicine, Bern University Hospital, Bern, Switzerland.
  • Beldi G Department of Visceral Surgery and Medicine, Bern University Hospital, Bern, Switzerland. guido.beldi@insel.ch.
Show more…
  • 2018-07-25
Published in:
  • Journal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract. - 2018
English BACKGROUND
Primary closure of post-operative facial dehiscence (FD) is associated with a high incidence of recurrence, revisional surgery, and incisional hernia. This retrospective study compares outcomes of implantation of non-absorbable intra-abdominal meshes with primary closure of FD. The outcomes of different mesh materials were assessed in subgroup analysis.


METHODS
A total of 119 consecutive patients with FD were operated (70 mesh group and 49 no mesh group) between 2001 and 2015. Primary outcome parameter was hernia-free survival. Secondary outcome parameters include re-operations of the abdominal wall, intestinal fistula, surgical site infections (SSI), and mortality. Kaplan-Meier analysis for hernia-free survival, adjusted Poisson regression analysis for re-operations and adjusted regression analysis for chronic SSI was performed.


RESULTS
Hernia-free survival was significantly higher in the mesh group compared to the no mesh group (P = 0.005). Fewer re-operations were necessary in the mesh group compared to the no mesh group (adjusted incidence risk ratio 0.44, 95% confidence interval [CI] 0.20-0.93, P = 0.032). No difference in SSI, intestinal fistula, and mortality was observed between groups. Chronic SSI was observed in 7 (10%) patients in the mesh group (n = 3 [6.7%] with polypropylene mesh and 4 [28.6%] with polyester mesh). The risk for chronic SSI was significantly higher if a polyester mesh was used when compared to a polypropylene mesh (adjusted odds ratio 8.69, 95% CI 1.30-58.05, P = 0.026).


CONCLUSION
Implantation of a polypropylene but not polyester-based mesh in patients with FD decreases incisional hernia with a low rate of mesh-related morbidity.
Language
  • English
Open access status
hybrid
Identifiers
Persistent URL
https://sonar.ch/global/documents/169832
Export to…

Statistics

Document views: 45 File downloads:
  • Full-text: 0