Intramedullary headless screw fixation for fractures of the proximal and middle phalanges in the digits of the hand: a review of 31 consecutive fractures.
Giesen TPlastic and Hand Surgery Department, University Hospital of Zurich, Zurich, Switzerland t_giesen@hotmail.com.
Gazzola RPlastic and Hand Surgery Department, University Hospital of Zurich, Zurich, Switzerland.
Poggetti APlastic and Hand Surgery Department, University Hospital of Zurich, Zurich, Switzerland.
Giovanoli PPlastic and Hand Surgery Department, University Hospital of Zurich, Zurich, Switzerland.
Calcagni MPlastic and Hand Surgery Department, University Hospital of Zurich, Zurich, Switzerland.
2016-04-09
Published in:
The Journal of hand surgery, European volume. - 2016
English
UNLABELLED We present the results of 26 patients with 31 consecutive displaced or unstable extra-articular fractures of the base and shaft of the proximal and middle phalanges of the digits of the hand, treated over a period of 12 months with an intramedullary headless compression screw and early mobilization with no splinting. All fractures healed with no major complications. Only one patient, who had a pathological fracture through an enchondroma, required a tenolysis to improve the mobility of the finger. This technique seems to be technically simple, effective and with few drawbacks.